To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 168 of 5194

Improve PI Server Installation kit: disk space requirements should include the minimal PI Backup

When calculating the disk space requirements on a recent upgrade the drive was expected to have only 138 MB installed. But the install failed due to not enough disk space on the drive because the minimal backup needed a certain amount of disk spac...
Nathan Skitt over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

PI AF Link & PIBatch - Ability to uninstall it

PI AF Link is not included in PI 2018 but it would be good to be able to remove the link during an upgrade. (not possible today https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000027668). Same for PIBatch which cannot be unins...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

AI Detection for Stale Points

As a PI System administrator, it would be helpful if the PI Server had an artificial intelligence or machine learning system which could recognize the normal updating patterns of a PI Point and report when a tag was not receiving updates properly ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Provide a MUI Kit for the Data Archive / SMT

Provide a MUI Kit for the Data Archive / SMT
David Scott almost 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Le vi over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status