To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 199 of 5257

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 In development

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani 7 months ago in PI to CONNECT / General 0 No status

Queue PI Point creation attempts if made during archive shifts

Currently, when archives are shifting, any attempts to create PI Points will be rejected with the error "Error on internal point editing call during point create for archive add point(<point info>). [-11095] Archive Shift already in progress...
Ryan Biggins 10 months ago in AVEVA™ PI Server / Data Archive 0 No status

Rename overwritten archive files with new start time when using Archive_OverwriteDataOnAutoShiftFailure

When using the Tuning Parameter, "Archive_OverwriteDataOnAutoShiftFailure", the system uses the oldest registered archive as the new primary. But it keeps the name of the old archive. It would be very helpful if the archive subsystem could rename ...
kliffhopson 5 months ago in AVEVA™ PI Server / Data Archive 0 No status

Add new PIPointAttribute for "StaleTimeout"

While no customers have asked for this directly, I have seen many customers ask how to check a tag for being stale. The solution to date assumes all tags have the same staleness timeout, which really is not the case most of the time. This new "St...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Guest about 1 year ago in PI to CONNECT / General 0 No status

Add failover / high availability for the PI to AVEVA Data Hub Transfer Agent

Right now, the Transfer Agent is a single point of failure. We need to be able to install at least one additional Transfer Agent, on a separate host, so that we can guarantee that our PI System data will arrive in AVEVA Data Hub. This will also al...
Daniel Lopez over 2 years ago in PI to CONNECT / General 0 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 4 No status

Provide more granular configuration for default ACLs

As a PI Administrator of a PI System with complex security requirements, I need to set up different default permissions for various users so they can create tags that automatically have the proper security instead of having to rely on a process/pr...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 No status

Support of Event Frame Annotations

Sometimes, annotations in Event Frames are stored (e.g. when acknowledging/commenting a notification in PI Vision). This information should get replicated to CONNECT data services and be made available through CONNECT visualization services. The o...