To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Notification delay setting similar to True For on EF Gen analysis

Allow the ability to configure a delay in sending Notifications so that they would only send if the triggering event frame is open for a configurable amount of time. This is possible at the analysis level using the True For setting; however, this...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 0 No status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss about 4 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest about 4 years ago in PI Interfaces / Other Interfaces 1 No status

PI AutoPointSync status bar resize

In the PI AutoPointSync (APS) Configuration and Management Utility, there is a status bar in the bottom right corner that indicates the status and time of the currently syncing interface. If the server's name is long enough, this field gets trunca...
Jacob Moe 6 months ago in PI Interfaces / General 0 No status

Add functionality to tables to make it more dynamic and easier to configure in a format.

As a notification user I want to see a table of all the attributes and its values on the target element in my email, furthermore when I add or remove attributes I want to see it automagically updated in my email without me having to reconfigure th...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 1 No status

Support for Entry of an Coresight Adhoc Display Link in a Notification Email

(AF 2016 R2, Notifications 2016 R2) I would like to have support to include a link to an Coresight ad-hoc trend for a specific attribute into an email. I have attempted to use the Insert Link option under Message formats in the following way: Ent...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 0 Declined

Notification if a tag is overfilling my Archive

As a PI admin I want to get notified if a tag is overfilling my Archive, maybe due to misconfiguration of ex/Comp. Setting.
meierke1 about 4 years ago in AVEVA™ PI Server / Notifications 4 Declined

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest about 4 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest about 4 years ago in PI Interfaces / PI Interface for UFL 1 Declined

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.