To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Provide the asynchronous communication PI Notification

Allow the notification system to be configured to establish synchronous or asynchronous communication according to the user's needs.
Guest about 4 years ago in AVEVA™ PI Server / Notifications 1 Declined

XML or other flat file Delivery channel

Would like to see the ability to create XML or other flat files from PI Notifications as was available in previous versions. We have seen cases where the network that the PI system resides on is locked down to the point that only flat files can be...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 0 No status

Include Creation date in event frame properties for Notifications

We see issues where notifications appear to be delivered late but then find the event frame was created at a later time than the actual event because of connectivity issues. Having the creation date of the event frame exposed for a notification wo...
Guest about 4 years ago in AVEVA™ PI Server / Notifications 2 No status

Ability to modify SOAP xml format

There are some cases when the sender wants to modify the format of the SOAP xml itself. Currently Notifications service constructs a XML request including all the variables provided by the wsdl.
Guest about 4 years ago in AVEVA™ PI Server / Notifications 0 No status

Alert user when the interface discards values

Example:  When using a distribution tag, the number of tags returned and number of values sent to PI can be mismatched, due to missing aliases or data that does not need to be collected. It would be helpful to identify what values are droppe...
Guest about 4 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Upgrade the PI Interface Configuration Utility to use only the latest Microsoft Visual C++ Redistributable

The PI Interface Configuration Utility install kit currently includes both the 2012 and the 2019 Microsoft Visual C++ Redistributables. Please upgrade the PI Interface Configuration Utility so that it requires only the latest Microsoft Visual C++ ...
Kenneth Barber about 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Request for customizing the order of the interface instances in PI ICU interface list.

The interface instances` names contain the plants `names and I want to put the interfaces with the same plant name together in the list.
Guest about 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 No status

PItoPI should switch from COLD to WARM failover instead of exiting

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, older versions supported COLD failover. In the case of upgrading the interfaces, ...
Guest about 4 years ago in PI Interfaces / PI to PI Interface 2 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status