AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 348 of 5192

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Uni-Int to write to scan-class health tags on startup

We've noticed this particularly with the RDBMS-PI interface when configured for failover: Health tags that are only written to when the interface becomes primary or has completed its first scan (eg Point Count, Scan Class I/O Rate etc.) say 'Intf ...
Guest over 3 years ago in PI Interfaces / General 0 No status

Separate commonly used PI Interfaces that do not have a successor into read-only and write-only versions

Currently, it is recommended to use the read-only version of a PI Interface if only reading is required, and to have separate read and write instances of the read-write version of a PI Interface if writing is required. (Reference: https://docs.osi...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

Allow using SQL as a data source for FactoryTalk Batch

Rockwell FactoryTalk Batch v12.01 allows to output batch data to a SQL database as well as EVT files. Just like with EMDVB, the PI Interface for FTBatch should be able to use both data sources.
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined

OPC AE: add history recovery feature

There is a stronger market demand to have more alarm data in PI so that the alarms can be analysed together with the process data. Existing (as of Oct 2019) PI OPC AE Interface does not support history recovery. Without the history recovery featur...
AM(CSL) over 3 years ago in PI Interfaces / Other Interfaces 0 No status

PI AMI Itron Interface support for TLS1.3

PI AMI Itron Interface currently supports TLS1.1. Microsoft ended support for TLS1.1 in March 2020. To keep the PI AMI Itron Interface usable with latest browsers, please update to support TLS1.3.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 Evaluating

OMF: Binary data format support

Provide a binary data format option in addition to JSON in the OSIsoft Message Format (OMF) spec.
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 0 Declined

OMF: Ability to patch data messages

Add the ability to provide partial information for an existing data point. This is meant as a partial update which replaces values for some properties of a type without affecting others.
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 0 Planned

OMF: the possibility to set/create security settings (groups …) by using OMF

After creating Elements and Tags in AF by using OMF standard, I don´t want to manually configure security settings in AF. The possibility to set/create security settings (groups …) by only using OMF standard would be very helpfull.
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 0 Declined

Allow OMF Health Authentication on PI Interfaces to Negotiate

Currently the OMF Health feature of PI interfaces only allows the interface to connect to the PI Web API OMF endpoint using Basic authentication. It would be good to see negotiate and windows authentication as an option like PI Adapters have to co...
Brian Rock 5 months ago in PI Interfaces / General 0 No status