To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 61

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 1 year ago in AVEVA™ Adapters / General 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
GaryYegiazaryan over 1 year ago in AVEVA™ Adapters / New Connectivity 3 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan over 1 year ago in AVEVA™ Adapters / General 1 No status

REST API data source

e.g.: weather forecast, 3rd party
Guest about 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status