To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 383 of 4902

BACnet SC/SuperConnect Support

Support for the BACnet SC/SuperConnect protocol for the PI Adapter, PI Connector, or PI Interface.
Connor Hawkins 8 months ago in PI Connectors / PI Connector for BACnet 0 No status

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 9 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col 9 months ago in PI Connectors / PI Connector for OPC UA 0 No status

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson 9 months ago in PI Connectors / PI System Connector 0 No status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Nico C 10 months ago in PI Connectors / PI Connector for BACnet 0 No status

Warning on PI Point Prefix value when adding a target PI Server

When creating a Destination PI Server on a Connector, it automatically gets assigned a default PI Point Prefix. Therefore if you delete and recreate a Destination PI Server, the Prefix will get reverted back to the default value. Please add a war...
Guest 11 months ago in PI Connectors / General 0 No status

PI Connectors/Relay/DCM be able to use GMSA accounts

When installing any PI Connector / Relay / Data Collection Manager, I am unable to use a GMSA account as part of the install. I'm able to go change the service afterwards but the service account requires a password in the installer (which there is...
kevin.brashears 11 months ago in PI Connectors / Installation 0 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh about 1 year ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Automatically updating digital state sets with PI System Connector

Add a feature to the PI System Connector so that it updates automatically digital state sets on the Destination Data Archive when edited on the source Data Archive. Currently PI System Connector replicates digital state sets referenced by the PI p...
Guest about 1 year ago in PI Connectors / PI System Connector 0 No status

PI Connector for Cygnet - Add support for disconnected startup

Add a disconnected startup option to improve startup times for connectors with high point count, or systems that have variable network conditions.