To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3248

Increase the discoverability of the windows that are accessible by right-clicking on the Operations pane

In PI System Explorer → Management, with the Analysis radio button selected, right-clicking in the Operations pane gives the user access to additional windows. Even though this is documented, it is not very discoverable. Users do not expect right-...
Kenneth Barber about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

close/open event frames based on events, not transitions

I use analysis to toggle a boolean or integer from 0 to 1. This is used as source to close/open event frames (step continious mode). this is working fine in real-time. But when I do a recalculation for a part of time in the past (not until *) on t...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

split analysis is real-time and recalculation part (different logic to be used)

It would be nice if we could have a "real-time" and "recalculate" part in an analysis. As source data could have changed you probably want sometimes the analysis to act in another way. Example: 2 attributes are used to trigger an event-triggered a...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

PI Analysis Service Running/Not Running Tag/Notification

There should be a way to monitor if the analysis service is running, other then just checking if its running from services, or that analysis service is not connected on PSE. There are no specific performance monitor counters that monitor such a th...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Analysis output type identified in statistics

Add some metadata to analysis statistics to identify which analyses are outputting to PI Points, which are configured as an Analysis Data Reference and which are a mix of both. Currently this isn't identified and can cause some confusion. For exam...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow TagVal to select a specific value if several values stored at a same timestamp

We have cases where we have several values for the same tag at a specific timestamp. When we use tagVal in an analysis expression, the TagVal function returns the last stored value for the timestamp for the tag. We would like to be able to get (us...
jerome.boudon about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Initial value for HasValueChanged

When an Expression or Event Frame Generation analysis evaluates for the first time, the function HasValueChanged returns True even if the value has not actually changed. More proper behavior would be to default to false. The same holds true when m...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Autobackfilling did not complete: Interval exceeds maximum allowed limit

Upon an analysis service restart, the service will backfill and recalculate for the time range specified by the MaximumAllowedAutoBackfillingSpanInHours service configuration parameter; the default is 72 hours. Starting in PI Analysis Service 2.8....
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI Integrator for Business Analytics extend the decimal places

Found out that the decimal points is up to 3 decimal only. Can you improve the PI Integrator that has its own decimal places? and also not depending on the AF for adjusting the display digits? Thanks
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

give AF users the option to choose the write mode of an analysis in real time (replace existing value at a given timestamp, or not)

When having calculationWaitTimeInSeconds set to a large value in combination with an AF-SDK app triggering recalculations, it can happen that recalculation writes a value at timestamp x before this analysis is triggered to run in real-time for tim...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status