To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 324 of 5120

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar 3 months ago in PI Interfaces / Other Interfaces 0 No status

Support for the VT_UI4 data type

As a PI System User I would like to archive and analyse VT_UI4 data using the PI System.
Guest almost 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support float64 point type in PI Interface for China Network Isolator

China Network Isolator interface does not support float64 point type, which is required by many customers in China. Right now, they have to change the point type to string first and then to float64 by analytics, this will consume two times of lice...
Guest almost 3 years ago in PI Interfaces / Other Interfaces 3 No status

OPC Alarms&Events interface should natively support event frame creation

As a PI Interface for OPC Alarms & Events user that would like to leverage AF Event Frames for more advanced analysis, I would like for the OPC AE interface to have an option to natively create event frames that open when a Status = Active mes...
Guest almost 3 years ago in PI Interfaces / Other Interfaces 2 No status

Include MSXML with the latest version of the PI Interface for OPC XML-DA

The Read-Only version of the PI Interface for OPC XML-DA (1.7.3.40) does not contain the msxml4 library necessary for communicating with the OPC XML-DA. The workaround is to install the Read-Write version of the interface and then the Read-Only ve...
Randy Giguere 5 months ago in PI Interfaces / Other Interfaces 1 No status

Enhance the OPC Interface to specify which groups are not receiving data

When a polled group does not receive data for more than 2 scan cycles, the interface updates the device status health point to 5 | Error | One or more groups not getting data. It will be useful to also specify which scan classes did not receive da...
Guest almost 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

EMDVB - Add Option to End Procedure EF with batchview.endtime equivalent instead of when it's unloaded from the BOI

Currently the EMDVB interface will not end the parent Procedure level event frame until the batch has been unloaded from the Delta Batch Operator Interface. It is very common for users to leave batches loaded for quite a while which causes batches...
Bill Sublette 4 months ago in PI Interfaces / Batch Interfaces 0 No status

Support Regex engine in the message filters

It would be nice to have regex matching and replace in PI UFL ini files. Also, would be nice to have anything other than ASCII encoding support (ex UTF-8..with/without BOM, etc) Use cases: ex. we need to parse timestamps where year has either 2 o...
Guest almost 3 years ago in PI Interfaces / PI Interface for UFL 1 No status

Enhancement for Advise tags to poll  OPC server when Excmax expires

Currently, when an advise tag does not get a value in an ExcMax period,  the interface will send the same value to PI over again without going to the OPC server (assuming that the OPC interface has not disconnected from the OPC server during ...
Guest almost 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest almost 3 years ago in PI Interfaces / Batch Interfaces 5 Planned