Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 1263 of 4879

Use the AUDIT filegroup for all CDC tables

When enabling auditing, the default CDC tables are created within the ASSETS filegroup in SQL, while all replication tables are created in the AUDIT filegroup. It would be good if all CDC tables were in the AUDIT filegroup so that all of the audit...
Rory BD 5 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott 6 months ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Enhance Analysis Template Search Option in PSE Management Tab

When searching by Template in PSE Management tab all analysis templates are returned in the drop down list. This can result in hundreds of options being listed depending on the size of the AF Server and database. This makes it very complicated and...
Mario Carioni 6 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates.

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates. Currently if we have say 4 attributes in an element template, and some instance elements have a couple of those "excluded", ...
Zubin Najmi 6 months ago in AVEVA™ PI Server / Notifications 0 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Guest 6 months ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Gregory Malek 7 months ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Lionel Gergaud 7 months ago in AVEVA™ PI Server / Data Archive 2 No status