Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 304 of 4893

Add an option to receive real-time data in client during buffer recovery

Add an option to receive real-time data in the client during recovery of buffered data: The default behaviour of our interfaces / buffering is that after a connection failure the buffer will be flushed and data will be sent in it’s original order...
Guest about 2 years ago in PI Interfaces / General 5 No status

Customize UniInt Failover Sync File Permissions

Prior to UniInt v4.6.0.60, UFO sync files created during interface startup would inherit file permissions from their parent folder (assuming child inheritance had been enabled on the folder). With UniInt v4.6.0.60, this behavior changed and now s...
Guest about 2 years ago in PI Interfaces / General 1 No status

PI Interface for SNMP accounting for Dynamic OIDs

Certain MIB files use dynamic indices which make dynamic OIDs. As the interface uses OIDs in the instrument tag manual action is needed to repair it should the OID change. This is particularly prevalent when using the HOST-RESOURCES-MIB, which use...
Guest about 2 years ago in PI Interfaces / Other Interfaces 3 No status

Support dynamic indexes from Linux devices for PI Interface for SNMP

When the interface machine needs to be restarted for any reason, the connection to the source (when a Linux device) is lost because Linux uses dynamic indexes and the Interface does not have a way to manage that. Tags need to be reconfigured every...
Laurie Dieffenbach 4 months ago in PI Interfaces / Other Interfaces 1 Declined

Conversion Factor with PItoPI interface

I would like to use a Conversion Factor for some PI Points that retrieve data via PI to PI. For example, on the source server the data is in volts. I would like to convert this data to kilo volts on the destination server.
Guest about 2 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface get data from FTP Server

No description provided
Guest about 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

EFGEN - Allow for null/blank values to be Zeroth State for active point

When my EFGen Active Point tags have a null value, the interface should be able to designate this as a Zeroth State.
Guest about 2 years ago in PI Interfaces / Batch Interfaces 4 Tell us more

Link Referenced Elements from Unitprocedure to Procedure Event

When Eventframe Batches are created by a Batch Interface, the used Unit in the plant is created as Element in AF and linked to the Unitprocedure EventFrame. Unfortunately it is not linked to the parent Procedure Event, leaving the "referenced Elem...
juergen.b.schmidt about 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock about 2 years ago in PI Interfaces / Batch Interfaces 1 No status

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo about 2 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined