To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 242

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server. There are documented known issues related to the slow ICU loading...
Guest 4 months ago in PI Interfaces / Other Interfaces 0 No status

Conversion Factor with PItoPI interface

I would like to use a Conversion Factor for some PI Points that retrieve data via PI to PI. For example, on the source server the data is in volts. I would like to convert this data to kilo volts on the destination server.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Add an option to receive real-time data in client during buffer recovery

Add an option to receive real-time data in the client during recovery of buffered data: The default behaviour of our interfaces / buffering is that after a connection failure the buffer will be flushed and data will be sent in it’s original order...
Guest over 2 years ago in PI Interfaces / General 5 No status

Customize UniInt Failover Sync File Permissions

Prior to UniInt v4.6.0.60, UFO sync files created during interface startup would inherit file permissions from their parent folder (assuming child inheritance had been enabled on the folder). With UniInt v4.6.0.60, this behavior changed and now s...
Guest over 2 years ago in PI Interfaces / General 1 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

EMDVB Data Type Enhancement

Please include option in the DeltaV EMDVB interface that can handle the timestamp format used with .evt files. Currently, if in the interface a trigger is used with a property, the timestamp format in the .evt file is retained, which cannot be sto...
Gary Moore 2 months ago in PI Interfaces / Batch Interfaces 0 No status

PI UFL Interface get data from FTP Server

No description provided
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Link Referenced Elements from Unitprocedure to Procedure Event

When Eventframe Batches are created by a Batch Interface, the used Unit in the plant is created as Element in AF and linked to the Unitprocedure EventFrame. Unfortunately it is not linked to the parent Procedure Event, leaving the "referenced Elem...
juergen.b.schmidt over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest 5 months ago in PI Interfaces / PI Interface for OPC DA 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest 5 months ago in PI Interfaces / Batch Interfaces 0 No status