To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 382 of 4876

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest about 2 years ago in PI Connectors / General 0 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer about 2 years ago in PI Connectors / General 5 No status

PI Connector for ICCP

Implementation a connector that supports the ICCP TASE 2 protocol
marcogiunti about 2 years ago in PI Connectors / New PI Connector Request 2 Declined

PI Connector for Apache Kafka / Confluent

Dear Connector Experts, for our Enterprise data integration project we have the need to use Apache Kafka / Confluent as the "data highway". This requires to send data to PI DA/AF from Kafka and also to read from PI DA/AF back into Kafka. I know ...
Gerrit Stapper about 2 years ago in PI Connectors / New PI Connector Request 3 Declined

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha about 2 years ago in PI Connectors / General 1 No status

Make the UFL Connector logic development/testing/debugging process less tedious

Deploying a UFL Connector solution requires a LOT of edits of the INI file as part of the development/testing/debugging process. After each INI file change and file save, the required procedure is as follows: 1. Click on the Data Source List link...
Mic Paluszak about 2 years ago in PI Connectors / PI Connector for UFL 0 Declined

Allow options to alter the way the connector handles different qualities (bad, questionable)

At this time, the connector does not expose any way to alter the way data of different qualities (bad, good, questionable) is handled. The PI OPC Interface allows several different options with regards to “quality” such as "send only GOOD quality ...
Gabriel Verreault about 2 years ago in PI Connectors / PI Connector for OPC UA 1 Declined

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector...
Steve Hampton about 2 years ago in PI Connectors / PI Connector for OPC UA 2 No status