Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 320 of 5050

Add an option to receive real-time data in client during buffer recovery

Add an option to receive real-time data in the client during recovery of buffered data: The default behaviour of our interfaces / buffering is that after a connection failure the buffer will be flushed and data will be sent in it’s original order...
Guest over 2 years ago in PI Interfaces / General 5 No status

Customize UniInt Failover Sync File Permissions

Prior to UniInt v4.6.0.60, UFO sync files created during interface startup would inherit file permissions from their parent folder (assuming child inheritance had been enabled on the folder). With UniInt v4.6.0.60, this behavior changed and now s...
Guest over 2 years ago in PI Interfaces / General 1 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest 5 months ago in PI Interfaces / PI Interface for OPC DA 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest 5 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest 5 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest 5 months ago in PI Interfaces / Batch Interfaces 0 No status

PI UFL Interface get data from FTP Server

No description provided
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

EFGEN - Allow for null/blank values to be Zeroth State for active point

When my EFGen Active Point tags have a null value, the interface should be able to designate this as a Zeroth State.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 4 Tell us more

Link Referenced Elements from Unitprocedure to Procedure Event

When Eventframe Batches are created by a Batch Interface, the used Unit in the plant is created as Element in AF and linked to the Unitprocedure EventFrame. Unfortunately it is not linked to the parent Procedure Event, leaving the "referenced Elem...
juergen.b.schmidt over 2 years ago in PI Interfaces / Batch Interfaces 0 No status