Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 306 of 4906

Enhance pitopi.ini sections to include point source to make them unique

The pitopi.ini file is used by the pitopi interface for collecting data from multiple sources and to save other miscellaneous settings such as 'histonly' flags. The configuration ini file uses sections to separate settings between instances with a...
Guest about 2 years ago in PI Interfaces / PI to PI Interface 2 No status

PItoPI should give indication when it is stuck querying a corrupt source archive

Currently, PItoPI interface can get "stuck" if it is querying a source data archive that is corrupt with no indication that this is what's happening.  It appears to be sending data to the destination server, but no data is received.  It ...
Guest about 2 years ago in PI Interfaces / PI to PI Interface 1 No status

Support Analysis Backfill of Source Tag

Many of our source tags sending data to a central Data Archive are populated with data from analyses on the source AF Server. This creates two problems when we perform a backfill that recalculates data over a specified timespan for the source tag:...
Guest about 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Uni-Int to write to scan-class health tags on startup

We've noticed this particularly with the RDBMS-PI interface when configured for failover: Health tags that are only written to when the interface becomes primary or has completed its first scan (eg Point Count, Scan Class I/O Rate etc.) say 'Intf ...
Guest about 2 years ago in PI Interfaces / General 0 No status

Enhance element creation to use user defined element templates

The interface can automatically create an element at each level of event frames, but the elements do not derive from a template and there is no way to specify any attributes on the element. The enhancement request is to create elements that are ba...
Guest about 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EMDVB Interface - Rename Parsed Files

PI EMDVB Interface - Rename Parsed Files.  Files that get renamed to .999 is no longer available with PI EMDVB.  This file renaming feature was very useful from a system maintenance perspective.  We would easily remove .999 from the...
Guest about 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest about 2 years ago in PI Interfaces / Batch Interfaces 1 No status

Add a Trace Route feature to PI Ping interface

Add ping -i feature to the interface and allow for either the output of the ping time or destination in the PI tag. Case: This will allow for IT to monitor the network path taken in communication from one site to another. If the route has change...
Guest about 2 years ago in PI Interfaces / Other Interfaces 0 No status

OPC AE: add history recovery feature

There is a stronger market demand to have more alarm data in PI so that the alarms can be analysed together with the process data. Existing (as of Oct 2019) PI OPC AE Interface does not support history recovery. Without the history recovery featur...
AM(CSL) about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest about 2 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status