Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3248

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow data sources and servers to be renamed

Currently, if you want to rename a data source, PI Data server, or PI Asset server, you must delete the one with the old name and create a new one with the new name, and redo all of the configuration. This is especially a pain for data sources, si...
Kenneth Barber about 2 years ago in PI Connectors / General 0 No status

Certified Power App Connectors to read and write PI Server data

Microsoft Power Apps enable low-code development of connectors to integrate data sources and applications. Rather than customers developing and maintaining their own connectors, it is requested that OSIsoft develop, maintain, and update a connecto...
Elizabeth McErlean about 2 years ago in AVEVA™ PI Server / General 0 No status

Standard Connector for Microsoft PowerPlattform

To use the PI Server with the Microsft PowerPlatform, a custom connector is required. This connector is always under the responsibility of the customer, which makes it difficult to keep up with adjustments to the PI system and Microsoft, or to rea...
Guest about 2 years ago in AVEVA™ PI Server / General 0 No status

Have the entered data from PI Manual Logger Web be view-able from the PI Point trend and historical data table without refreshing.

It is very important in the case of downtime to see the changes in Manual Logger Web immediately to ensure the downtime and run-time events are accurately measured. Therefore having the data not update immediately in the tag trend display in the m...
Guest about 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Extract events from buffer queue files or offline archives

Currently, the procedure to recover buffer queue files consists of parsing the queue file into a temporary archive and then merging this archive with the registered archive files that overlap with the impacted period. This final merge requires to ...
pspeybro about 2 years ago in AVEVA™ PI Server / Data Archive 1 No status

Option to install sample PI tags with simulator interfaces

Posted on behalf of a customer. As of PI Server 2018 SP3, simulator interfaces have been removed from the PI Server setup kit, and the default PI Points are no longer installed. These were very important to check if the server installation went w...
Guest about 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Separate priority setting for Data Read and Data Write

Data Read and Date Write (Buffering) from/to PI Data Archive is based on the priority settings in PI SDK and PSE. We have a architecture of 6 member PI collective and all the source data is not buffered to the individual collective. Hence for othe...
vasanth51 about 2 years ago in AVEVA™ PI Server / Data Archive 2 No status

Enable Data Fanning for PI Collectives through PI System Management Tools

Currently, PI System Management Tools supports buffering but not data fanning (does not send data to all collective members). When using a PI Collective, customers would like to make changes to PI Point values in Archive Editor in the Primary Dat...
Guest about 2 years ago in AVEVA™ PI Server / Data Archive 1 No status