To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 311 of 4928

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 2 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest over 2 years ago in PI Interfaces / Other Interfaces 1 No status

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 2 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 2 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 1 Declined

Allow PItoPI APS connector to sync "Point Type" changes

Currently (as of PI to PI Interface AutoPointSync Connector Version 1.5.0.7), it's not possible to sync changes to "Point type". (See pg 5 of user manual). Please make this possible in a future release.
Guest over 2 years ago in PI Interfaces / General 0 Declined

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee over 2 years ago in PI Interfaces / General 1 Declined

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 2 years ago in PI Interfaces / Batch Interfaces 4 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance WMI interface to verify that ACE Class Libraries are running

PI-ACE Manager looks at the PI-Module Database to see if the individual modules are running. The Class Library sub-processes updates the PI-MDB when it starts & stops. If the process dies, it does not always update the PI-MDB values. So, there...