Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My subscriptions

Showing 3248

Allow the boxes in PI System Explorer's Security Configuration window to be vertically resized

In PI System Explorer → File → Database → Edit Security, the border under the "Items to Configure" box and above "Identities" and "Permissions for" should be adjustable. This would allow "Items to Configure" to grow and the other 2 boxes to shrink...
Kenneth Barber about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

AF external table cache

We have some central tables which we want to be accessible for all AF users like the central telephone directory (to add information about maintenance contacts for example). This table is quite big in a company with several thousands of employees ...
juergen.b.schmidt about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

When calling PI Point data values using RelativeTime, the timestamp should show the time of that value not the time of the call.

When calling PI Point data values using RelativeTime, the timestamp should show the time of that value not the time of the call. In PI Server 2012 the time of the value was shown when using the RelativeTime call from PI System Explorer. In the PI ...
Nathan Skitt about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Expose whether or not an attribute template is overridden on the element in PI System Explorer

When I override an attribute template on an element (for example, changed descriptions), it would be useful to see some sort of flag on the attribute in PSE to let me know that it’s no longer linked to the template
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Alphabetize Selections in drop downbox when creating filters in EF, etc.

In PI System Explorer, when creating a filter for looking at Event Frames, in the dropdown box, the selection items aren’t sorted in alphabetic order.  It is an arduous task to review each of the selections to pick the one that you want. It w...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Improve selecting inputs for Formula DataReference with large number of attributes

When an element has a large number of attributes defined (e.g. 400), then it is very difficult to select an attribute as an input to the Formula DataReference because the dropdown does not have a scroll bar.
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add an error message when applying UOM to string value type attribute

When changing the value type to string of an attribute with an associated UOM, the following error is observed: "...cannot be changed to type 'String' because it has a unit of measure and 'String' does not support UOMs." When you have an existin...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

AF SDK vs claim authentication

We currently have an issue with Docker based windows applications that we cannot enable windows authentication due to outdated AD architecture. Once suggestion is that we use claims based authentication, but this will only work for PI Web API and ...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Allow Table Link to be installed on AF Client

Since it's already possible to import a table through an AF Client, it would be nice to be able to do the same for Table Links. Currently doing so results in an error: "Unable to link to external table: Unexpected Server Error". See KCS: "Unexpe...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Ability to create a list of frequently used Contacts for use in PI Notification

The option for users to create a list of commonly used Contacts for use in PI Notifications subscribers would save the hassle of individually searching contacts each time members are added to a subscription. Additionally, using Contact Groups are ...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status