Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

My subscriptions

Showing 391 of 5213

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Bring back the online Hardware and PI System Sizing recommendations web page

Bring back the online Hardware Sizing Tool (HWST) that was popular with customers and OSIsoft employees. Although a downloadable spreadsheet is available here: https://customers.osisoft.com/s/productcontent?id=a7R1I000000Xz7KUAS the online version...
Guest over 3 years ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

Support https instead of http only

No description provided
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 2 Future consideration

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 8 months ago in AVEVA™ Adapters / General 0 No status

Make it easier to find products in the customer portal

Finding products is a real pain. It would be much easier if you were to let me search for products first, then show me where they are licensed in the sites/servers that I belong to, and in the same screen show me if the licenses are current. Right...
Guest over 3 years ago in Customer Portal & PI Square / Product Downloads 1 No status

Provide a list of all software components, including their quantities and end dates, for each site.

It is important to have visibility into the products associated with each license, including their usage quantities and expiration dates
Somchai Limwongsaree 2 months ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

system requirements

Product Search Please bring back the old list of products that listed the current version of the product and system requirements. Even if we don't yet have the license for a product, this older mechanism made it much easier to find information.
Bill Sublette over 3 years ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned