To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 319 of 5192

Allow Creation of Acknowledgeable Event Frames

The PI Web API exposes a "CanBeAcknowledged" property when reading Event Frames. However, this property is read-only: it cannot be supplied when creating a new Event Frame or updating an existing Event Frame. I would like the ability to include th...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 No status

Writing to AF Table through PI Web API

Currently PI WebAPI provides only the method UpdateData /Put Tables (https://techsupport.osisoft.com/Documentation/PI-Web-API/help/controllers/table/actions/updatedata.html) to insert data into an AF table and this method requires the entire table...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

Make PI Web API responses more descriptive or allow developers to configure their own custom response fields.

Currently if a PI Web API user attempts an action which is not allowed, the error handling is somewhat generic. Stream and Stream Set controller calls might contain an additional information in the response fields, but not always. e.g. Trying to ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 1 No status

Drop support for TLS 1.0 and TLS 1.1

The blog post linked below urges customers to disable TLS 1.0 and TLS 1.1 but also mentions that PI Web API supports them. https://pisquare.osisoft.com/s/Blog-Detail/a8r1I000000GvqGQAS/tls-best-practices-for-pi-web-api Please drop support for TLS ...
Kenneth Barber over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow configurable number of TCP connections

PI Web API is limited to 20 active TCP connections per user. Any attempt to go over the 20 TCP connection limit results in a TCP reset packet for the requesting username / IP address. Request to have a parameter to adjust the limit. Also requestin...
Luke Peters over 1 year ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 0 No status

Defining "Scan Class" and "Poll" Capabilities in Aveva Adapter for Azure Event Hubs

Define the "Scan Class" and "Poll" capabilities in the Aveva Adapter for Azure Event Hubs, similar to the functionality available in the Interface. Ensure the ability to manually select a "Scan Class" for PI Points and define it as "Poll".