To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes

Showing 4912

Clamp Value at Limit

Ability to clamp or ignore values outside a threshold. Example would be to clamp the low value to 'zero' attribute and/or a high value at 'span' - many xmtrs read erratically when at limit (e.g., an empty flow transmitter often reads negative)
Pete Long about 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Automatically recreate advise groups when they are discarded by RSLinx OPC Server

The Rockwell RSLinx OPC Server may discard advise groups when there are too many bad quality tags or incorrect ItemIDs added to the group. The PI Interface for OPC DA should automatically recreate advise groups after it has determined that the gro...
Guest about 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCClient able to sort List of all structure instances

PI OPCClient able to sort List of all structure instances. Currently: Chronologically is pretty annoying. While listing the content of opc server structure, the folders are not listed alphabetically. While there are many items, export is not po...
ivan.mudron about 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

AMI Interface: allow meter data to be writable to PI Point attributes

Synced to PI Square at https://pisquare.osisoft.com/ideas/29455 Currently, meter data can only be written to static attributes. Historizing the meter data may be useful if there are expected changes that should be monitored.
Guest about 2 years ago in PI Interfaces / General 0 Declined

Allow Buffer to communicate with other buffer

Currently the PI Buffer Subsystem only has the capability to speak directly with the Data Archive. This setup can have a negative impact on your Cyber Security setup as you are not able to leverage the DMZ between the IT/OT networks as it is desig...
Shaun Longworth about 2 years ago in PI Interfaces / General 0 Declined

Make UserID and ReviewerID available from BatchQuestion table for PI Interface for Wonderware InBatch

Currently UserID (DoneBy_User_ID) and ReviewerID (CheckBy_User_ID) cannot be read from the BatchQuestion table when using PI Interface for Wonderware InBatch. These fields are important to know who answered the question and who confirmed/checked t...
Guest about 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

WonderWare InBatch - change phase state logic when a phase end event occurs at the same time as phase start event

When a phase end event is received at the same time as a phase start event, the WWInBatch interface currently creates batches/event frames of zero duration despite there being phase state events under the phase event. It would be helpful if the in...
Guest about 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

Allow the Event Frame Templates to be fully customizable in the PI Interface for EMDVB

Allow the Event Frame Templates to be fully customizable. This will give the flexibility to remove attributes like Product from the PIBatch and Procedure, as it is represented in the lower levels of Event Frames.
Nathan Skitt about 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Change sequencing in PI Interface for Emerson DeltaV Syncade Batch for improved data analytics

Please view attached PDF
Guest about 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

Data Verification for the PI Interface for Emerson DeltaV Batch

Add a feature that performs a verification check of the data in PI against data in the DeltaV Historian and provide a report of any missing or mismatched data.
Guest about 2 years ago in PI Interfaces / Batch Interfaces 1 Declined