To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 318

Separate commonly used PI Interfaces that do not have a successor into read-only and write-only versions

Currently, it is recommended to use the read-only version of a PI Interface if only reading is required, and to have separate read and write instances of the read-write version of a PI Interface if writing is required. (Reference: https://docs.osi...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

OPC AE: add history recovery feature

There is a stronger market demand to have more alarm data in PI so that the alarms can be analysed together with the process data. Existing (as of Oct 2019) PI OPC AE Interface does not support history recovery. Without the history recovery featur...
AM(CSL) over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Option to disable DataLink automatic grouping

As a creator of DataLink spreadsheets, I would like to have the option to disable DataLink automatic grouping so that I can apply an input to one function (ex. filter expression, conversion factor, etc.) without it being applied to the entire grou...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 1 No status

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Allow OMF Health Authentication on PI Interfaces to Negotiate

Currently the OMF Health feature of PI interfaces only allows the interface to connect to the PI Web API OMF endpoint using Basic authentication. It would be good to see negotiate and windows authentication as an option like PI Adapters have to co...
Brian Rock 5 months ago in PI Interfaces / General 0 No status

Enhance pitopi.ini sections to include point source to make them unique

The pitopi.ini file is used by the pitopi interface for collecting data from multiple sources and to save other miscellaneous settings such as 'histonly' flags. The configuration ini file uses sections to separate settings between instances with a...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 2 No status

PItoPI should give indication when it is stuck querying a corrupt source archive

Currently, PItoPI interface can get "stuck" if it is querying a source data archive that is corrupt with no indication that this is what's happening.  It appears to be sending data to the destination server, but no data is received.  It ...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Support Analysis Backfill of Source Tag

Many of our source tags sending data to a central Data Archive are populated with data from analyses on the source AF Server. This creates two problems when we perform a backfill that recalculates data over a specified timespan for the source tag:...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status