To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3547

Make PI ICU to support gMSA for Service creation

gMSA are the way of having secured logins for windows services and we try to spread the awareness to switch from standard user accounts to these account type. However as most of the PI applications supports to define the gMSA during installation o...
Ondřej Kafna about 1 year ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Return row number from PI SQL Client calls

It would be useful to be able to access a specific row from a PI SQL Client call. For example if I query muiltiple attributes indicating some KPI ordered from highest to lowest returning 1000 rows, I might want to show only the top 10. The TOP fun...
Simon J. Dyson over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Allow the SDK connection priority for the RTQP Engine to be configurable

The RTQP Engine is currently only able to connect to the Primary Data Archive to retrieve data, regardless of the SDK Priority settings. The “PreferPrimary” connection priority is hardcoded into the RTQP engine and cannot be modified. For users wh...
Derek Wong over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 2 No status

Have pre-made PI Identities with minimum permissions by default

It currently takes more effort to follow AVEVA's recommendation of setting minimum permissions for all PI service accounts than it is to use fewer service accounts with more permissions. To help steer PI administrators in the right direction, plea...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 2 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Wonderware Historian Connector should store some metadata in PI tag attributes

The Description, Maximum EU, Minimum EU, Engineering Units, etc. that are stored in the Wonderware historian should be stored in the PI tags' attributes as well as the Wonderware AF structure.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

Improve the structure of the history recovery after connector restarts to ensure that initial period of history recovery is complete

The 30-day history recovery by the connector after restarts should get activated only after the initial history recovery is confirmed to have completed successfully.
Guest over 3 years ago in PI Connectors / PI System Connector 0 No status

Adjust GE e-terraHabitat Connector to support e-terraPipeline systems

The Pi Connector for GE e-terraHabitat systems was apparently only written to support GE's Electrical SCADA systems (EMS/DMS) that are based on e-terraHabitat. They also have Oil & Gas Pipeline SCADA systems, also based on e-terraHabitat, know...
KPRoth over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Have the entered data from PI Manual Logger Web be view-able from the PI Point trend and historical data table without refreshing.

It is very important in the case of downtime to see the changes in Manual Logger Web immediately to ensure the downtime and run-time events are accurately measured. Therefore having the data not update immediately in the tag trend display in the m...
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Enable Data Fanning for PI Collectives through PI System Management Tools

Currently, PI System Management Tools supports buffering but not data fanning (does not send data to all collective members). When using a PI Collective, customers would like to make changes to PI Point values in Archive Editor in the Primary Dat...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status