Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Support user-defined data types in the PI Connector for EtherNet/IP

As an advanced user, I would like to be able to specify a user-defined data type for the array sent to the PI Connector for EtherNet/IP.  For example, if I have a 32-bit array composed of one INT and two SINTs, I would like to be able to conf...
Guest about 4 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Synchronize behavior between PI Connector for Cygnet and Cygnet enumeration value representation

The values stored in the “Table Entry” column in Cygnet TRS should match the “State” column in the PI Server Digital states table. This way end users are not confused why the trends in PI do not match the trends in Cygnet.
Guest about 4 years ago in PI Connectors / PI Connector for CygNet 0 No status

Allow PI system Connector to be Redundant

This product is pushing production data... it should be redundant.
taterhead247 about 4 years ago in PI Connectors / PI System Connector 2 No status

Allow rename of tags for IEC-60870-104 connector

The connector should allow sending the data to a custom tag name. The combination of ASDU and IOA are not useful to end users without the signal list. There should also be an option to automatically combine the quality flags with the value e.g. i...
sahilp about 4 years ago in PI Connectors / Other specific PI Connector 0 No status

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 about 4 years ago in PI Connectors / Other specific PI Connector 0 No status

Exclude Bad values from data collection in PI Connectors

PI connectors such as OPC UA, Wonderware and Cygnet send BAD values from the data source. We would like the option to filter these values out at the connector level such that they do not make the PI Data Archive.
Guest about 4 years ago in PI Connectors / General 0 No status

Poly function should allow number attributes as coefficients

The current Poly function does not support attributes as coefficients, so we need to revert back to using Pow. This makes the Poly function of little additional benefit. We need to be able to use any numeric attribute as input for the Poly coeffi...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

I would like the ability to move searches defined on the PSE management tag from computer to computer

I have created numerous searches on the management tab of the PSE, but if changing computers or even sharing the searches between workers you currently have to recreate the searches on each computer. Not sure where these are stored currently, but ...
Steve Hampton about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Provide options to connect PI Analysis service either to Primary or Any collective members

As a PI server Administrator I would like to have a way to decide the PI DA collective member Analysis server should connect. This will allow us to manage better the load on PI DA
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Retain cell formatting after PI Builder "Retrieve" actions

When I use datalink, it will not overwrite my cell formatting like background color. When I use PI Builder to retrieve data, it overwrites all cell formatting. Can you please edit your PI Builder code to behave more like Datalink in regard to pres...
Guest about 4 years ago in AVEVA™ PI Server / PI Builder 4 No status