Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302

choose PI API Version during installation

At the moment PI API 1.x without Windows Integrated Security is installed as standard. For customers who want to use PI API 2.x with Windows Integrated Security an additional installation is needed. please include both APIs in install-pack and ask...
FranzK almost 2 years ago in PI Interfaces / Installation 2 Declined

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to it's...
jagdish.konathala almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No Status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Support data collection across data diodes or similar technology

Regulatory and/or security requirement to separate data collection from data storage using a one-way data flow. Could apply to Interfaces or Connectors, for example PI Interface for Emerson Ovation. PI Interface/Connector -> one-way data flow ...
Guest almost 2 years ago in PI Interfaces / General 0 No Status

Suppress creation of an AF Element hierarchy

As a PI Admin, I may have already created a AF Element Hierarchy corresponding to my BES or MES source data. Therefore I have no need for the interface to create a new AF Elements and I would like to suppress this completely.
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

RDBMS to Eventframe Batch Interface

a lot of your existing Batch Interfaces are based on RDBMS (Simatic Batch, DeltaV, ABB). But there will always be some Batchstorage solutions based on a relational database which are not included in your source system list. For now Honeywell Proce...
juergen.b.schmidt almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI Event Frames Interface Manager

Hello, the PI Event Frames Interface Manager application must be run in the same machine that hosts the PIEFGen interface. This is an issue regarding our security rules because, the PIEFgen interface runs in secured machines and we don't want to a...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined