Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest 11 months ago in PI Interfaces / PI to PI Interface 0 No Status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to it's...
jagdish.konathala almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No Status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Support data collection across data diodes or similar technology

Regulatory and/or security requirement to separate data collection from data storage using a one-way data flow. Could apply to Interfaces or Connectors, for example PI Interface for Emerson Ovation. PI Interface/Connector -> one-way data flow ...
Guest almost 2 years ago in PI Interfaces / General 0 No Status

Meter Type support for REXU-EA

PI Interface for EnergyAxis to support REXU-EA meter types.
leanderb@ntua.com almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

Suppress creation of an AF Element hierarchy

As a PI Admin, I may have already created a AF Element Hierarchy corresponding to my BES or MES source data. Therefore I have no need for the interface to create a new AF Elements and I would like to suppress this completely.
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

RDBMS to Eventframe Batch Interface

a lot of your existing Batch Interfaces are based on RDBMS (Simatic Batch, DeltaV, ABB). But there will always be some Batchstorage solutions based on a relational database which are not included in your source system list. For now Honeywell Proce...
juergen.b.schmidt almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined