Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4902

Improve the structure of the history recovery after connector restarts to ensure that initial period of history recovery is complete

The 30-day history recovery by the connector after restarts should get activated only after the initial history recovery is confirmed to have completed successfully.
Guest about 2 years ago in PI Connectors / PI System Connector 0 No status

Allow PI System connector to actively rectify streams if point type changes are made during runtime

Point changes on the source currently necessitate a restart of PI System Connector to rectify the streams. Allow the tau framework to handle these changes at runtime without restarting the connector. Currently, if the point type changes are made ...
Guest about 2 years ago in PI Connectors / PI System Connector 0 No status

Collect units of measure and description from Siemens Simatic PCS 7

Support collecting units and description from the Siemens Simatic PCS 7 system and writing them to the AF attribute and the PI Point attributes.
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

Allow rename of tags for IEC-60870-104 connector

The connector should allow sending the data to a custom tag name. The combination of ASDU and IOA are not useful to end users without the signal list. There should also be an option to automatically combine the quality flags with the value e.g. i...
sahilp about 2 years ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow data sources and servers to be renamed

Currently, if you want to rename a data source, PI Data server, or PI Asset server, you must delete the one with the old name and create a new one with the new name, and redo all of the configuration. This is especially a pain for data sources, si...
Kenneth Barber about 2 years ago in PI Connectors / General 0 No status

Failover for PI Connector Relay

Although, the PI Connector Relay going down / not being available does not cause data loss since the connector data is buffered, if the source connector supports Failover, the relay becomes the only single point of failure in the data flow. Havi...
Gabriel Verreault about 2 years ago in PI Connectors / General 4 Declined

Allow specifying conditions (or case constructions) for ParentID/ElementID functionality

Allow specifying conditions (or case constructions) for ParentID/ElementID functionality. Example: if [1].Value=x then ParentID=[2].value ElementID=[3].Name    else if [1].Value=y then ParentID=[4].value ElementID=[3].Name   ...
Guest about 2 years ago in AVEVA™ PI Server / General 0 Declined

Certified Power App Connectors to read and write PI Server data

Microsoft Power Apps enable low-code development of connectors to integrate data sources and applications. Rather than customers developing and maintaining their own connectors, it is requested that OSIsoft develop, maintain, and update a connecto...
Elizabeth McErlean about 2 years ago in AVEVA™ PI Server / General 0 No status