Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 383

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest 8 months ago in PI Connectors / PI Connector for OPC UA 0 No status

Link to user manual/ help file unavailable from UI

The connector UI does not contain any link to the help documentation or the user manual. The files are also not found in the standard PIPC path and are available only with the installation extarction
Guest about 2 years ago in PI Connectors / Help / Documentation / Videos 0 No status

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim about 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Validate credentials before running connector

Need a way to easily confirm that the credentials are correct before I try and run the connector.  Would like to see any errors surfaced via the web page so I can troubleshoot.
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

PI Connector for Wonderware Historian should automatically create digital PI Tags

Currently the connector creates all discrete Wonderware tags with a Point Type of Int32. As a PI System Administrator, I would like the connector to have the option to create these tags as digitals and automatically create their respective Digital...
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

The PI Connector for Wonderware Historian should automatically populate the point attributes Zero and Span when creating PI Tags.

As a PI System Admin, I would like the PI Connector for Wonderware Historian to automatically populate the point attributes Zero and Span when creating PI Tags so that these attributes do not have to be manually edited after the tags are created.
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Option to replicate PI Point security attribute with PI System Connector

The current version of PI System Connector does not support replicating the PI Point security attributes: •Point Security •Data Security •Data Access •Data Group •Data Owner •Point Access A further option would be to automatically create an...
Guest about 2 years ago in PI Connectors / PI System Connector 1 Declined

Allow PI system Connector to be Redundant

This product is pushing production data... it should be redundant.
taterhead247 about 2 years ago in PI Connectors / PI System Connector 2 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest about 2 years ago in PI Connectors / Other specific PI Connector 0 Declined