Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Interfaces

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest about 4 years ago in PI Interfaces / Other Interfaces 0 No status

Create a user friendly OPC HDA Tool to replace the current one

No description provided
Gabriel Verreault about 4 years ago in PI Interfaces / Other Interfaces 0 No status

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest about 4 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest about 4 years ago in PI Interfaces / Other Interfaces 0 No status

Allow OMF Health Authentication on PI Interfaces to Negotiate

Currently the OMF Health feature of PI interfaces only allows the interface to connect to the PI Web API OMF endpoint using Basic authentication. It would be good to see negotiate and windows authentication as an option like PI Adapters have to co...
Brian Rock about 1 year ago in PI Interfaces / General 0 No status

Add TCP option to PI UFL Interface

Currently the only two options are file reading or a serial interface. But what if you have ASCII data streaming from a TCP/telnet source? The configuration would be almost the same as serial - for the connection, rather than a serial port, just n...
John Alessio about 1 year ago in PI Interfaces / PI Interface for UFL 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth almost 4 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Prevent AutoPointSync from using SYSTEM Digital state set

AutoPointSync automatically assigns the SYSTEM Digital State set to Digital tags, this should be prevented as it can create confusion and issues down the road.
Guest over 1 year ago in PI Interfaces / General 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest about 4 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status