Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 1291

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Mike Horrocks 4 months ago in AVEVA™ PI Server / Data Archive 0 No status

Provide more granular configuration for default ACLs

As a PI Administrator of a PI System with complex security requirements, I need to set up different default permissions for various users so they can create tags that automatically have the proper security instead of having to rely on a process/pr...
Guest over 2 years ago in AVEVA™ PI Server / Data Archive 2 No status

Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
taterhead247 over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Ability to change the timezone used in PI System Explorer with a feature similar to what is found in PI DataLink or PI SMT 2017.

As an end user, I would like to be able to change the timezone referenced in PI System Exporer from client timezone to server timezone. Something similar to the "PI Data Archive Time Zone"  setting found in PI DataLink would be helpful.
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 8 No status

Add support for multiple SortFields in AF Search

Currently, AF search results can only be sorted by a single field. It would be useful to have the capability to specify 2 (or more) SortField values so that the order of results can be guaranteed in the result of a tie. For example, being able to...
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 month ago in AVEVA™ PI Server / Notifications 0 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek 3 months ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 2 years ago in AVEVA™ PI Server / Data Archive 4 No status

Show Child Attribute in Analysis PE Editor Auto-Complete

As a user configuring Analyses, I would the the Performance Equation (PE) Editor's auto-complete to suggest any child attributes as well as regular attributes.  Note: This was previously Enhancement 109589.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Date Format in AF Event Notification

In AF please provide a way to suppress time zone and/or to format the timestamp in AF Events, particularity, Notifications. For example, in the message format in e-mail notification I do not need to indicate the time zone it was triggered in. Ple...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 3 No status