To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4910

Configurable OSIsoft\PI Connectors\UFL.ConnectorHost\ location defined during installation

Currently, the folder is created by default in %ProgramData%, which means that the output folder, storing the processed file, is created in %ProgramData%\OSIsoft\PI Connectors\UFL.ConnectorHost\Output\{DSName}\. Since %ProgramData% is generally o...
Gabriel Verreault about 2 years ago in PI Connectors / PI Connector for UFL 1 No status

UFL Connector - Add elements and attributes to existing AF hierarchies

Simply, it would be nice if the UFL Connector could add to existing elements and attributes already in place instead of creating a new hierarchy. Also, would like the ability to create sub-elements from the UFL connector that span multiple eleme...
Guest about 2 years ago in PI Connectors / PI Connector for UFL 0 Declined

Allow users to rename PI Connector for UFL point source

PI Connector for UFL allows for configuring point prefix, but does not allow for modifying point source. Some users prefer browsing tags by point source, and may want separate point sources for different UFL connectors.
Guest about 2 years ago in PI Connectors / PI Connector for UFL 2 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest about 2 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Enhance connection logic to source PI server during Interface startup

When PitoPi Interface starts up, it prints a message saying that it secured a connection with the Target or Host PI server as follows:  PIAPI Successfully connected to :5450. Then it begins to load target PI points and it starts looking for t...
Guest about 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Add functionality to the interface to adjust timestamps by a configurable amount

This enhancement would add the ability to adjust timestamps to the PI to PI Interface (Beyond the included options for clock drift and subseconds). Potentially, a setting could be supplied to change the timestamps on all data transferred by a spec...
Guest about 2 years ago in PI Interfaces / PI to PI Interface 1 No status

Please add a DAYOFWEEK function to the UFL interface

Can you please add a DAYOFWEEK function to the available functions in the UFL interface. This will greatly assist with the handling of daylight savings transitions (e.g. first sunday in April) as there is currently no easy way of determining the ...
Guest about 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

UFL Designer should include a test mode to verify INI behavior with a data file.

One can do this, to some extent, piecemeal with functionality the UFL Designer already has. However, it's a very manual process and does not actually have a way to show what data would be sent to PI for a particular file. An explicit test mode or ...
Guest about 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest about 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest about 2 years ago in PI Interfaces / PI Interface for OPC DA 2 No status