Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Interfaces

Showing 328

Support for Key Pair Authentication

Currently, PI ICU authentication relies on traditional username/password methods. However, this authentication approach is becoming increasingly obsolete and is not supported by many of the modern platforms and security frameworks we are required ...
Kareema Ramli 2 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest about 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest about 3 years ago in PI Interfaces / Other Interfaces 2 No status

PI BACNET interface support BACnet Intrinsic Reporting (BIR)

PI BACNET interface should support BACnet Intrinsic Reporting (BIR). It allows PI BACNET interface to subscribe alarm information. We will not miss the alarms if it will be implemented.
Kenji Hashimoto 2 months ago in PI Interfaces / Other Interfaces 0 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida 7 months ago in PI Interfaces / PI Interface for OPC DA 0 No status

SNMP Interface to support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.

SNMP Interface should support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.
Guest about 3 years ago in PI Interfaces / General 0 No status

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey about 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

PI Interface for Foxboro I/A 70 Series should support Windows 2016 and I/A Version 9.4

The PI Foxboro Interface should support the new Foxboro platform on Windows Server 2016 and I/A Version 9.4.
neuhach1 about 3 years ago in PI Interfaces / Other Interfaces 2 Evaluating

For PItoPI interface having a source PI-HA collective, allow failover on source automatically.

This enhancement would allow the PItoPI interface to treat a source PI collective as a collective, rather than requiring PItoPI failover to be specified for collective members.
Heather Boehler about 3 years ago in PI Interfaces / PI to PI Interface 3 Tell us more