Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Interfaces

Showing 252

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

SNMP Interface to support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.

SNMP Interface should support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.
Guest over 3 years ago in PI Interfaces / General 0 No status

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida 7 months ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support for Key Pair Authentication

Currently, PI ICU authentication relies on traditional username/password methods. However, this authentication approach is becoming increasingly obsolete and is not supported by many of the modern platforms and security frameworks we are required ...
Kareema Ramli 3 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

PI BACNET interface support BACnet Intrinsic Reporting (BIR)

PI BACNET interface should support BACnet Intrinsic Reporting (BIR). It allows PI BACNET interface to subscribe alarm information. We will not miss the alarms if it will be implemented.
Kenji Hashimoto 3 months ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for OPC AE Instrument tag any attibute should work

As now it is just Source and Area event attributes that work for the instrument tag. It should be possible for any attribute to work as a filter in instrument tag. It is not every OPC AE server that supports Source and Area.
Hobbe over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Support for the VT_UI4 data type

As a PI System User I would like to archive and analyse VT_UI4 data using the PI System.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support float64 point type in PI Interface for China Network Isolator

China Network Isolator interface does not support float64 point type, which is required by many customers in China. Right now, they have to change the point type to string first and then to float64 by analytics, this will consume two times of lice...
Guest over 3 years ago in PI Interfaces / Other Interfaces 3 No status