Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Showing 1347

Event Frames that can expire/auto-delete/archive

When generating Event Frames it would be useful to automatically remove the Event Frame, either when no longer active or in combination with no longer active and acknowledged, or other conditions. An example use case would be for PI Notifications...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Value at End Time in PI Notifications 2.X

It would be nice to have the ability to drag and drop the value at end time of  an attribute in the message format of a Notification. We can do this with the value at start time and the value at send time, but not the value at end time. There...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Notification when message sent to Delivery Endpoint is rejected

When a notification is sent to a delivery endpoint (web service) and the message is rejected, no failure notification is shown within PSE.  In order to track this issue I currently have to sift through the log files looking for exceptions suc...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 2 No status

Provide a means to parse/extract data from the response received by PI Notifications after sending a notification to a web service endpoint

A web service endpoint, for instance ServiceNow, may response with useful information to a notificate, like a ticket number. There should be a way to associate that information with the event frame that triggered the notification.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 2 No status

Remove Templates for Elements in PI System Explorer

Currently, when you remove a template from an Element in PI System Explorer, you'll remove all existing attributes from the Element. There should be a functionality in PI System Explorer to remove the template without making changes to the attrib...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Improve PI Data Security

The assignment of a PI tag on which the currently logged in user has no authorization as PI point reference to an AF attribute must not (as currently) be possible. It is possible to bypass the PI Archive authorization mechanism (point and data sec...
GünterSendlinger over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 5 No status

A way to specify within analyses whether input values should be retrieved from the Data Archive or the PIAF Cache

A way to specify within the analyses if input values should be retrieved from the Data Archive or the PIAF Cache. Thereby preventing different results during real-time calculation and for instance backfills and decreasing the execution time of ana...
David Scott over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Include logs for when an AF database is deleted in the AF event viewer logs

Currently, to confirm when an AF database has been deleted + by which user, AF audit trail needs to be enabled. Audit trails tend to take up a lot of space and many users decide not to enable them. It would be beneficial to include logs each time ...
Guest about 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add Function to Determine if a Bit is Active in a Word Value

It would be extremely helpful if a function existed within PI AF where could provided a value/tag reference and a bit number to check and see if its active. The function would return a True or False value if that bit is active. Something like the ...
Justin Jackson 2 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Utility to completely uninstall all OSIsoft PI products from a machine

It would be helping to have a utility do a complete uninstall of all the PI products from a machine including registry keys and hidden files.
Guest over 3 years ago in AVEVA™ PI Server / Installation 2 Declined