Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 406

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Create a user friendly OPC HDA Tool to replace the current one

No description provided
Gabriel Verreault over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 10 months ago in PI Interfaces / Batch Interfaces 0 No status

accept relative time period as historical start time for transfer settings

Business requirement to re-transfer dataset due either to network or server related issue(s).
Guest over 2 years ago in PI to CONNECT / General 1 No status

Better align AVEVA CONNECT data services Asset Type to AF template

Right now, PI to CONNECT agent creates empty asset types for the assets it creates.Additionally, if you connect multiple agents which have the same templates (or the same template names), these will all be created as empty asset types.If the Asset...
Guest over 2 years ago in PI to CONNECT / General 2 No status

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose almost 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Guest almost 2 years ago in PI to CONNECT / General 0 No status