Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Showing 863

Update description of existing elements and analysis when template description is updated

When a element or analysis template description is changed, descriptions of existing elements or analyses are not updated. The description is only updated when the element or analysis is created. A customer has proposed the following options: I...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 4 No status

Allow AF to use any PI Point metadata (descriptor, UoM, Compression, etc.) as Attributes.

Some metadata can be used in Analyses, which is helpful, but means constantly running an analysis on static data in order to use it at all in AF, which is inefficient, and we have been told to pull in data as a linked table into AF, which seems un...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Further development of PI AF scripting functions

In many UseCases we need more programability functions in PI. As example loop functions. We like the AF Framework, beacuse if you search in case of a problem you are very fast. But the functionaclity is unfortunatly not very rich. Please integrat...
photi24 over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Allow Notifications to be sent via MQTT

Allow adding MQTT brokers as Delivery Endpoints for notifications.
Kevin Wood 6 months ago in AVEVA™ PI Server / Notifications 0 No status

Include filtering logic in asset analytics

In Asset Analytics, there isn't a way to include a filtering function in a single analytic. For example, you may be calculating run hours on a motor, but there is no way to filter the calculation so that it is only done when the motor is running.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Include Attribute UOM function in AF similar to TagEU

This would allow for validation of input unit of measure during expressions.
Mike Horrocks 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Pi System Explorer: Display Check-In History Per User

I would like to be able to see a log of when users checked in changes to the system in PSE. I recently checked in changes to our PSE system and around the same time, the CPU pegged of SQL server and the analyses slowed way down and other functiona...
Jonathan Gibbs 7 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Do not require permission to PIPOINT if the permission is already covered by Point Security or Data Security

https://docs.osisoft.com/bundle/pi-server/page/permissions-required-for-tasks.html According to the documentation linked above, when permission to Point Security or Data Security is required, the same permission to PIPOINT is also required. This i...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 2 No status

Add filtering and rolling log system to AFGetTrace

When troubleshooting intermittent issues, using AFGetTrace may be problematic as the trace can consume quite a bit of disk space, and setting a maximum file size will cause the trace to stop once the file is full. Without knowledge of when the iss...