Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Export Data Supports Data Frequency

As a process engineer, I would like to be able to control the data frequency (minute, hour, etc.) of how much data is exported for my time range rather than a fixed number of data points SO THAT the data that I export can actually be used for some...
Guest about 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 3 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber about 4 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

Add ability to check adapter level failover status

Currently it is not possible to check the adapter failover state in the utility. Still requires using edgecmd get failoverstate to check which adapter is primary / secondary and view failover score, adapter status and last processed time.
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 Evaluating

Include support for no Stream ID Prefix

Leaving the Stream ID Prefix empty in the utility for the components data source sets NULL in the .json file. This results in adding a prefix to the stream which can inadvertently cause new streams to be built in the data archive instead of sendin...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 1 Planned

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest about 4 years ago in PI Connectors / General 1 No status

Allow writing arrays as a time series to an output

I would like to be able to configure outputs in an analysis to write at multiple time points (which are defined by the result of an array function). My use case is to: 1. Configure an attribute as a Time Series Table Lookup 2. Create an analysi...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 Tell us more

PI Collective Member monitoring

Actually there is no direct way to get the information in PI Vision mentioning to which member of the collective the server is connected , we have the same topic with PI Analysis , there is no direct way so monitor the member of the collective tha...
dgenet about 2 months ago in AVEVA™ PI Server / Data Archive 0 No status

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / General 4 Future consideration

Replication of tag attributes

Provide the possibility to manually select replication of tag attributes as stream metadata. Besides None, Low, Medium, High in the Stream Metadata Replication Policy of a transfer there should be a "Custom" option to select additional tag attribu...
Hans-Otto Weinhold 5 months ago in PI to CONNECT / General 0 No status