To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 930

Include filtering logic in asset analytics

In Asset Analytics, there isn't a way to include a filtering function in a single analytic. For example, you may be calculating run hours on a motor, but there is no way to filter the calculation so that it is only done when the motor is running.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Allow Notifications to be sent via MQTT

Allow adding MQTT brokers as Delivery Endpoints for notifications.
Kevin Wood 7 months ago in AVEVA™ PI Server / Notifications 0 No status

Do not require permission to PIPOINT if the permission is already covered by Point Security or Data Security

https://docs.osisoft.com/bundle/pi-server/page/permissions-required-for-tasks.html According to the documentation linked above, when permission to Point Security or Data Security is required, the same permission to PIPOINT is also required. This i...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 2 No status

Add filtering and rolling log system to AFGetTrace

When troubleshooting intermittent issues, using AFGetTrace may be problematic as the trace can consume quite a bit of disk space, and setting a maximum file size will cause the trace to stop once the file is full. Without knowledge of when the iss...
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

PI Archive ability to recover from drive disconnect

With everyone having virtual servers these days the host VM and SAN storage are on separate devices. When the storage device is unavailable or disconnected even briefly, the PI Archive process errors and gets DISABLED and can ONLY be restarted by ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 No status

2 factor authentication

As a user, I would like PI Data Archive to provide 2 factor authentication.
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Which attribute triggered analysis

I have an analysis that is event-triggered by multiple attributes. This analysis has the purpose of merging input attribute events with output tag, therefore I need to know which attribute triggered analysis to save only the newest event to outpu...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add an analysis function to find the Kth largest value in an array

Expression analyses allow you to find the largest value of an attribute over a specified time range using the TagMax function. A function which offers the ability the find the Kth largest value (i.e. 2nd, 3rd, etc.) would be useful. Something simi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable Compression for recalculated Analyses up to "Now"

Analysis Recalculation produces Out of Order Events, which means they are not compressed. The reason for this behavior is, that there is a more recent snapshot value existing. This also happens, when Recalculation is performed till "Now" (*), beca...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status