Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 878

Event Frame Re-capture/Backfill Option to Save Annotations/Reasons

When a backfill or "recapture events" option is selected for Event Frames, give the user an option to "Save Annotations" for that specific event frame. Right now, we use Event Frames to copy in Reason Codes and Comments (that are logged as annotat...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Outputs at close available for all generation modes

‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'. If y...
MarkusKoschorreck over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Further development of PI Notification

Unfortunatly PI Notfication is an very old tool. The Tool is very old and slow. Improvements are needed. Improvements needed: 1. Performance Update for the engineering tool in the AF is very poor 2. Functionality to send an event to an webapi is...
photi24 over 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Ability to search find where specific UOM are used

As a user, I want to be able to find where specific UOM are used, so that I know the impact of UOM changes to my PI AF hierarchy.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Include Attribute UOM function in AF similar to TagEU

This would allow for validation of input unit of measure during expressions.
Mike Horrocks 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Pi System Explorer: Display Check-In History Per User

I would like to be able to see a log of when users checked in changes to the system in PSE. I recently checked in changes to our PSE system and around the same time, the CPU pegged of SQL server and the analyses slowed way down and other functiona...
Jonathan Gibbs 7 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Export Analysis Search

In the management tab of PSE, allow the option to export the defined analysis searches. When a user receives a new computer, all of the defined searches have to be recreated.When this spans development, quality assurance and production environment...
Tim Carmichael over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Allow Default Attribute to use inherited attributes

Derived templates (element and event frame) will not allow for inherited attributes to be used as the "Default Attribute". This breaks inherited analyses that use the "Default Attribute". The only workaround is to override the the attribute, which...
Mike Horrocks 7 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add option to clear buffer errors to the Buffering Manager

Currently users have to use the command line tools to clear buffer point errors. It would be useful and enhance O&M if these errors could be cleared directly from the UI rather than just viewed.Bonus points for allowing users to clear all, mul...
Shawn McNabb almost 2 years ago in AVEVA™ PI Server / System Management 0 No status

Option to ignore the digital state set ID in historical archive record headers and just use the one in the latest or in the point database.

If digital tags are found to be assigned to inappropriate digital state sets, changing the state set does not change historical data since the state set is also held in each archive record header. To correct the historical data, you have to offlin...
AlistairTCO over 2 years ago in AVEVA™ PI Server / Data Archive 0 No status