To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 798

Do not require permission to PIPOINT if the permission is already covered by Point Security or Data Security

https://docs.osisoft.com/bundle/pi-server/page/permissions-required-for-tasks.html According to the documentation linked above, when permission to Point Security or Data Security is required, the same permission to PIPOINT is also required. This i...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Security 2 No status

Conditional Analytics within event frame templates

As a PI Admin, I'd like to be able to calculate conditional based analytics within my event frames rather than in an outside calculation that you need to reference within the event frame. This causes timing issues when trying to schedule that calc...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Analyses Rollup should support Range and more functions

I want the Rollup to use the Range or Delta function.
Hobbe over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Notifications Time Zone Format

In Notifications 2016 R2, when configuring a custom Date format (via the TimeFormat attribute in the AF Configuration database), I would like an option to have the time zone display as EDT, PST, etc. The only option is to show it as a +/- offset f...
Guest over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Allow PI Buffer Subsystem (pibufss) to be managed by Powershell tools for the PI System

Powershell is a convenient way to administer a PI Server. One limitation, however, is that there is no built-in functionality for administering pibufss with powershell. Please add PI Buffer Subsystem (pibufss) management to Powershell tools for th...
Guest over 2 years ago in AVEVA™ PI Server / System Management 0 No status

several Instances for PI Relay

Having the PI Relay for OPC UA Connector running on a different machine than the actual connector is a good Idea, as we are now able to provide Windows credentials for AF Access without Credential manager. On our Site we are running several small...
juergen.b.schmidt over 2 years ago in AVEVA™ PI Server / System Management 0 No status

Data Collection Manager User management

We are running a central DCM Server in our site to maintain the dataflow between different UA Connectors and different DataArchive/AF pairs. We use this DCM to restart Connectors and to browse and select new Tags on a OPC UA Server. As central Ad...
juergen.b.schmidt over 2 years ago in AVEVA™ PI Server / System Management 0 No status

Harmonize Attribute Editor and Attribute Template Editor

Currently Attribute Template Editor and Attribute Editor behave different regarding visualisation of templates when using derived templates. Attribute Template Editor shows the attributes of the base template only if Group By Template is checked....
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 5 No status

Substitution Parameters for PI Point Exdesc

I would like to have an out of the box way for an attribute to display a pipoint exdesc. One thought would be able to have a substitution parameter that would point at the pipoints exdesc.
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Ability to manage non-impersonated linked tables without PI AF Server Admin privilegies

PI AF Admin would like grant permissions for users that are not level server admins to create and edit non-impersonated linked tables. Currently this only allowed for AF server admins or using impersonated linked tables. User guide: https://liv...
Guest over 2 years ago in AVEVA™ PI Server / Security 3 No status