Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1117

Add an analysis function to find the Kth largest value in an array

Expression analyses allow you to find the largest value of an attribute over a specified time range using the TagMax function. A function which offers the ability the find the Kth largest value (i.e. 2nd, 3rd, etc.) would be useful. Something simi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable Compression for recalculated Analyses up to "Now"

Analysis Recalculation produces Out of Order Events, which means they are not compressed. The reason for this behavior is, that there is a more recent snapshot value existing. This also happens, when Recalculation is performed till "Now" (*), beca...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Add the option to delete all event frames that reference an element when the element is deleted

When deleting an element using PI System Explorer, there should be an option to delete all event frames that reference the element. Currently when deleting an element, the delete option "Delete this object and all references to it" does not delete...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Event Frame Re-capture/Backfill Option to Save Annotations/Reasons

When a backfill or "recapture events" option is selected for Event Frames, give the user an option to "Save Annotations" for that specific event frame. Right now, we use Event Frames to copy in Reason Codes and Comments (that are logged as annotat...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Outputs at close available for all generation modes

‘Outputs at close’ is very powerful and flexible. It allows one to use expression analysis syntax in event frames. Unfortunately, it is only available for generation mode 'explicit trigger', but not for 'pulse', 'step', or 'step continuous'. If y...
MarkusKoschorreck over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Further development of PI Notification

Unfortunatly PI Notfication is an very old tool. The Tool is very old and slow. Improvements are needed. Improvements needed: 1. Performance Update for the engineering tool in the AF is very poor 2. Functionality to send an event to an webapi is...
photi24 over 3 years ago in AVEVA™ PI Server / Notifications 1 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Ability to search find where specific UOM are used

As a user, I want to be able to find where specific UOM are used, so that I know the impact of UOM changes to my PI AF hierarchy.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility.

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility. This should allow failover based on connectivity and/or a watchdog (like failover if a specific tag stay stale for a configurabl...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Allow the UFL interface to delete PI tag data or provide some other supported automated method of deleting PI data from a collective.

There is no way to easily delete data in a time range if you want the changes to occur on both the primary and secondary data archive. It seems the UFL interface would be good to use to do this. You could provide it a tag name and time range and t...
Heather Boehler over 3 years ago in PI Interfaces / PI Interface for UFL 3 No status