To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 311

Increase max. service ID for PI UFL Interface

According to https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=3645819457236571808-241124 , any number larger than 99 can NOT be specified for PI UFL Service ID. It would be better for us if the larger number such as 300 could b...
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Enhance OPC server failover capability

Need to trigger failover when a watchdog tag is stale for a configurable duration.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined

PI Interface for OPC DA retry writing data when it receives a CONNECT_E_ADVISELIMIT error.

I would like the ability for the PI Interface for OPC DA to retry writing data when it receives a CONNECT_E_ADVISELIMIT error. Certain OPC servers return a CONNECT_E_ADVISELIMIT error when write requests are received in quick succession, and havin...
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined

Clamp Value at Limit

Ability to clamp or ignore values outside a threshold. Example would be to clamp the low value to 'zero' attribute and/or a high value at 'span' - many xmtrs read erratically when at limit (e.g., an empty flow transmitter often reads negative)
Pete Long over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Automatically recreate advise groups when they are discarded by RSLinx OPC Server

The Rockwell RSLinx OPC Server may discard advise groups when there are too many bad quality tags or incorrect ItemIDs added to the group. The PI Interface for OPC DA should automatically recreate advise groups after it has determined that the gro...
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCClient able to sort List of all structure instances

PI OPCClient able to sort List of all structure instances. Currently: Chronologically is pretty annoying. While listing the content of opc server structure, the folders are not listed alphabetically. While there are many items, export is not po...
ivan.mudron over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

AMI Interface: allow meter data to be writable to PI Point attributes

Synced to PI Square at https://pisquare.osisoft.com/ideas/29455 Currently, meter data can only be written to static attributes. Historizing the meter data may be useful if there are expected changes that should be monitored.
Guest over 2 years ago in PI Interfaces / General 0 Declined

Allow Buffer to communicate with other buffer

Currently the PI Buffer Subsystem only has the capability to speak directly with the Data Archive. This setup can have a negative impact on your Cyber Security setup as you are not able to leverage the DMZ between the IT/OT networks as it is desig...
Shaun Longworth over 2 years ago in PI Interfaces / General 0 Declined