Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 92

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 1 year ago in AVEVA™ Adapters / General 5 Future consideration

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 2 years ago in AVEVA™ Adapters / General 3 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 2 years ago in AVEVA™ Adapters 2 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 1 year ago in AVEVA™ Adapters / General 1 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Allison Muraski over 2 years ago in AVEVA™ Adapters / General 3 Tell us more

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status