Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3536

Ability to disable recalculation at the Database level in AF

Currently backfilling and recalculation are only enabled and disabled at the global and element level. There are instances where users of Asset Analytics, particularly when it comes to event frames, experience automatic recalculation upon a servic...
zachary cmelak almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Upgrade PI Interfaces for BACnet

In testing of the PI Interface BACNet, the BVRATE value does not reflect the I/O Timeout value, even in the latest version. We are not sure if this behavior was originally intended or not. Please investigate the cause of this behavior and implemen...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col almost 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Nico C almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Warning on PI Point Prefix value when adding a target PI Server

When creating a Destination PI Server on a Connector, it automatically gets assigned a default PI Point Prefix. Therefore if you delete and recreate a Destination PI Server, the Prefix will get reverted back to the default value. Please add a war...
Guest almost 2 years ago in PI Connectors / General 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable the compatibility of PI Builder with Microsoft 365/O365

With the existing versions, the PI Builder plugin doesn't work with O365 in its full capability. It would be great to have the compatibility setup from PI Builder plugin with MS365.
Guest about 2 years ago in AVEVA™ PI Server / PI Builder 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add functionality to change the name of a PI Integrator publish target after its creation

Please add functionality to change the name of a PI Integrator publish target after its creation. For example, a SQL target was named after its server hostname. After the SQL server migration to a new server with a new hostname, we'd like to updat...
Ting-Ying Chung about 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status