To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1675 of 5192

Further development of PI AF scripting functions

In many UseCases we need more programability functions in PI. As example loop functions. We like the AF Framework, beacuse if you search in case of a problem you are very fast. But the functionaclity is unfortunatly not very rich. Please integrat...
photi24 over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Allow renaming of diagnostic tags for batch interfaces

Batch interfaces should follow a similar approach to UniInt based interfaces to retrieve the diagnostic tags. That is to say they should pull the diagnostic tags based on the PointSource, Location1, and ExDesc, not a hardcoded name based purely on...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

Add a Concat() function that can be nested into the other available functions for string builder

When using string builder attributes to dynamically generate specific values, additional attributes need to be created whenever concatenation of multiple attribute values is part the the logic. For example when using a string builder to generate a...
Randy Giguere 9 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Include filtering logic in asset analytics

In Asset Analytics, there isn't a way to include a filtering function in a single analytic. For example, you may be calculating run hours on a motor, but there is no way to filter the calculation so that it is only done when the motor is running.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Use dynamic endpoints to subscribe AF Groups to Notification Rules.

We have several sites, and a corresponding AF Group with personnel local to each site. We would like to configure the AF Element Template for sites to send a daily notification to the corresponding group for each site. This can only be done by add...
Gregory Malek about 1 year ago in AVEVA™ PI Server / Notifications 0 No status

Allow Notifications to be sent via MQTT

Allow adding MQTT brokers as Delivery Endpoints for notifications.
Kevin Wood 7 months ago in AVEVA™ PI Server / Notifications 0 No status

Do not require permission to PIPOINT if the permission is already covered by Point Security or Data Security

https://docs.osisoft.com/bundle/pi-server/page/permissions-required-for-tasks.html According to the documentation linked above, when permission to Point Security or Data Security is required, the same permission to PIPOINT is also required. This i...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 2 No status

Add filtering and rolling log system to AFGetTrace

When troubleshooting intermittent issues, using AFGetTrace may be problematic as the trace can consume quite a bit of disk space, and setting a maximum file size will cause the trace to stop once the file is full. Without knowledge of when the iss...
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

Apply correct localhost.tz file during PI Data Archive installation

To account for the different historical implementations of Daylight Saving Time in different regions, a localhost.tz file is added to the %piserver%\dat directory after installation. As an installer of PI Data Archive, I would like the localhost.t...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 Declined

PI Archive ability to recover from drive disconnect

With everyone having virtual servers these days the host VM and SAN storage are on separate devices. When the storage device is unavailable or disconnected even briefly, the PI Archive process errors and gets DISABLED and can ONLY be restarted by ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 No status