To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 762

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Guest 30 days ago in AVEVA™ PI Server / Analytics & Calculations 1 No Status

Support setting data quality related flags from analysis

As a user of Asset Analytics I would like to manipulate data quality related flags (such as quastionable, substituted, etc) from my analysis so that I can set the flag when there is a problem with input value statuses.
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 2 No Status

Powershell 7 (.NET Core) support for PowerShell Tools for the PI System module

No description provided
Gabriel Verreault over 1 year ago in AVEVA™ PI Server / System Management 2 No Status

Increase the sub seconds to be more that 3 decimal places in PSE UI

We faced an issue with thinking the formula DR time series data in PI System Explorer was duplicating results but that was because the sub seconds were not showing and there were difference in the sub seconds for the two results which we thought w...
Guest 10 months ago in AVEVA™ PI Server / Asset Framework (AF) 1 No Status

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Lionel Gergaud 2 months ago in AVEVA™ PI Server / Data Archive 2 No Status

Offer extended support for PI ProcessBook for security updates only past 2022

As other vendors do, offer customers the option to purchase extended support for PI ProcessBook for security updates only past 2022 for at least one year, and reevaluate annually based on number of customers interested. This would only apply to s...
Guest over 1 year ago in AVEVA™ PI Server / General 0 No Status

Allow output expressions when using implicit Event Frame generation modes

In AF/Analytics 2018, implicit modes of Event Frame generation were introduced (Pulse, Step, and Step Continuous), but they do not allow for an output expression like the explicit trigger. Adding this functionality would allow for EF attribute val...
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 2 No Status

Ability to send a notification without being triggered by an event frame

As a notification user I want to receive a report on daily or weekly basis but I don’t want to store any associated data about it like the event frame information or the notification history since I use event frames for other purposes and I don’t ...
Guest over 1 year ago in AVEVA™ PI Server / Notifications 2 No Status

Notifications for events in the past

Currently notifications are not triggered (send) by events that are more than 72 hours in the past. For me it is necessary to get notifications from events in the (endless) past. Ideally I would like to configure for each notification separately t...
Guest over 1 year ago in AVEVA™ PI Server / Notifications 7 No Status

Allow changes to pitimeout table (tuning parameters) to be audited

I can be helpful when tracking down issues or troubleshooting past events what the values of tuning parameters were at a given time. Adding the ability to Audit this table would allow retrospective insight into tuning parameter configurations. ...