To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 82

PI Interface DNP3 - unsolicited data listen only mode of operation requested

Is there an option in DNP3 driver (In fact at TCP level) to make it listen on a certain (usually 20000 for DNP3)? In era of IoT devices, most devices are sleeping devices, they wake up usually once a day and push data to DNP3 Master (PI), however ...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 1 Tell us more

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No Status

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Ellery Murdock almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No Status

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest almost 2 years ago in AVEVA™ Adapters / General 0 Future Consideration

Allow default settings (eg. disable compression) for tags created by Adapters

We would like to be able to specify default settings for tags created by the adapters. This would include things such as disabling compression for tags on this adapter (without disabling it as the default for all new tags on the Data Archive). Thi...
Guest almost 2 years ago in AVEVA™ Adapters / General 0 No Status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks 12 months ago in AVEVA™ Adapters / General 0 No Status

Allow restricting access to the Adapter to only allow configuration by specific users

We want to make sure that we have more control over who can update an Adapter. Is there a way to add a login or other restriction to only permit certain users to be able to modify Adapters, similar to how, with PI Connectors, only specific Windows...
Daniel Lopez 8 months ago in AVEVA™ Adapters / General 1 No Status

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK su...
Gabriel Verreault almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No Status

Expand PI Adapters to be installed on RedHat/CentOS

No description provided
Jessica Fegely almost 2 years ago in AVEVA™ Adapters / General 4 Tell us more

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Gabriel Verreault almost 2 years ago in AVEVA™ Adapters / General 1 Future Consideration