To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1461 of 5192

PI Analysis Performance Checker

Currently PI Analysis Service has a built-in Statistics tool in PI System Explorer. It is able to show statistics regarding Evaluation and Calculation Lag as well as Skipped Evaluations and some other important information. PI System Explorer ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Expose backfilling/recalculation status in the AFSDK

Currently analysis runtime information can be accessed programmatically using the AFSDK (AFAnalysisService.RuntimeInformationFields - https://techsupport.osisoft.com/Documentation/PI-AF-SDK/html/P_OSIsoft_AF_Analysis_AFAnalysisService_RuntimeInfor...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 4 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Add configurable defaults for PI Point "Pointsecurity" and "Datasecurity"

Read access to the PIPOINT table is required for most identities. Pointsecurity and Datasecurity currently use the settings on the PIPOINT table as the default. New points will generally give read access to most identities because of these default...
Guest over 3 years ago in AVEVA™ PI Server / Security 2 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 22 days ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow writing arrays as a time series to an output

I would like to be able to configure outputs in an analysis to write at multiple time points (which are defined by the result of an array function). My use case is to: 1. Configure an attribute as a Time Series Table Lookup 2. Create an analysi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Tell us more

Rename overwritten archive files with new start time when using Archive_OverwriteDataOnAutoShiftFailure

When using the Tuning Parameter, "Archive_OverwriteDataOnAutoShiftFailure", the system uses the oldest registered archive as the new primary. But it keeps the name of the old archive. It would be very helpful if the archive subsystem could rename ...
kliffhopson 2 months ago in AVEVA™ PI Server / Data Archive 0 No status

Enlarge area for editing analysis expressions

When editing an Analysis Expression, only 4.5 lines appear. It would helpful if more lines appeared (greater than 20 lines).
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status