Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Showing 1344 of 5209

Enable PI Point value retrieval methods for Digital PI Points.

We have found great use for the PI Point Value Retrieval Methods available for PI Point attributes. One such use is for displaying downtime percentage for numerous assets on a PI Vision page. The downtime percentage can be calculated for any inter...
Gregory Malek almost 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

New analysis to perform insert into AFTable

Hello, We have a use case that would benefit from being able to insert into an AFTable from an analysis. This would work in the same way that event frames do, where a trigger condition is meet that causes the row to be inserted. The variables from...
Trevor Flynn almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Higher Cache Time for PIEFGEN

A higher Cache time for the PI EFGEN would be great. Currently the limit ist 60 days.
SLeute over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Backup directly to AWS S3 bucket

We've successfully migrated our entire PI System into the AWS environment. Therefore it would be very nice if the pibackup.bat script would be able to directly backup to an S3 bucket.
ArieVanBoven over 1 year ago in AVEVA™ PI Server / Data Archive 1 No status

Store a timestamp of when an event enters the archive database

We have a use case that could be solved very easy if we have had this as a column in the data archive. Use case: We have made PI data availible through an own made API to our clients. They use this API to fetch data from our database and into thei...
Ole Dybsjord Skarsvag about 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Use the AUDIT filegroup for all CDC tables

When enabling auditing, the default CDC tables are created within the ASSETS filegroup in SQL, while all replication tables are created in the AUDIT filegroup. It would be good if all CDC tables were in the AUDIT filegroup so that all of the audit...
Rory BD over 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Apply Time Context to Other DRs in Event Frames

As this post points out, "The PI Point DR allows you to specify whether you want the StartTime or EndTime of the event frame. All other OSIsoft data references - most notably Table Lookup, Formula, StringBuilder - do not give you this option. Thos...
Kelsey Bobeck about 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Simpler performance analysis service statistics review directly in AF Explorer

Consider implementation performance analysis service statistics in AF Explorer which is now performed in a complicated way by exporting data to Excel, rearranging and viewing in a pivot table. It would also be useful to be able to retrieve that da...
igreguri about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status