Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

Status No Status
Product PI Connectors
Categories PI System Connector
Created by Guest
Created on Aug 20, 2022

Ability to exclude specific branches from syncing through PI Data Collection Manager

The PI Data Collection Manager User Interface has the options to "Collect All Data from this Entire Database" and "Collect Data from a Specific Branch". What we want to do instead is to "Collect All Data from this Entire Database EXCEPT from a specific branch". This is because the users in the target (test) database do not have permissions to configure the branch (element) that we want to exclude from syncing. The current workaround is to install a PI System Connector for each branch of the database that we want to include.
  • Attach files
  • Brent Bregenzer
    Reply
    |
    Aug 20, 2022
    I agree this would be a good feature.  Something that comes to mind as a possible workaround is to make a second duplicate hierarchy in the same DB that uses references to the original, but excludes the branch that you don't want to sync.  This 2nd hierarchy could then be the one used for PSC.  I haven't had a chance to test this, but I think it should be possible.  Please let us know what you think.
  • Allison Muraski
    Reply
    |
    Aug 20, 2022
    While the connector can’t exclude a branch, you can include multiple branches in the connector using multiple data sources. So instead of installing a PI System Connector for each branch, you configure a data source for each branch. Check out the data source configuration reference below, mainly the section on collecting data from a specific branch and let us know how that option may or may not be able to meet your needs. https://livelibrary.osisoft.com/LiveLibrary/content/en/con-pi-system-v2/GUID-B4EA033A-E8CB-49B1-B6DF-5148E1FCABC5